Home > products > Bulk CCTV Cable > 144*0.12AL Braiding USA Standard Rg6 Siamese Cable , Coaxial Cable For CCTV

144*0.12AL Braiding USA Standard Rg6 Siamese Cable , Coaxial Cable For CCTV

Product Details

Place of Origin: Hangzhou, China

Brand Name: OEM Produce

Certification: CPR

Model Number: RG6 Siamese

Payment & Shipping Terms

Minimum Order Quantity: 10km

Price: FOB Shanghai Price: 43.0USD/305m

Packaging Details: 100M. 200M. 300M. 1000FT. 500M. Reel

Delivery Time: 20days after deposit

Payment Terms: TT. LC

Supply Ability: 5000km/ Month

Get Best Price
High Light:

cctv lan cable

,

bulk network cable

Application:
Camer/ CCTV/ Telecommunication
Insulatioin:
Foam PE
Shield:
AL Foil+Braiding
Color:
Black PVC Or Customized
Power Wire:
2x18AWG CCA
Working Voltage:
12V DC/ 24V AC
Brand:
OEM
Packing:
1000Ft/ 305Meter
Application:
Camer/ CCTV/ Telecommunication
Insulatioin:
Foam PE
Shield:
AL Foil+Braiding
Color:
Black PVC Or Customized
Power Wire:
2x18AWG CCA
Working Voltage:
12V DC/ 24V AC
Brand:
OEM
Packing:
1000Ft/ 305Meter
144*0.12AL Braiding USA Standard Rg6 Siamese Cable , Coaxial Cable For CCTV

RG6U with Power Shotgun Cable 144*0.12AL Braiding USA Standard Siamese CCTV Cable

RG Series RG6 CCTV Coaxial cable                       

RG59 Standard:  1.02mm CCS+4.7mm FPE+16x9x0.12mm AL +7.0mm PVC+18AWG CCA Power Wire 65° Packing: 305m/Roll

Construction Material      Diameter(mm)
Inner Conductor    BC  1.02
Dielectric    Foam PE         4.7
First Shield       Bonded AL Foil       18#
Second Shield      CCA Braid     90%
Outer Jacket    PVC     WHITE 7.0
Power Wire Conductor CCA 18AWG
Power Wire Insulation PVC 1.9

Electrical Characteristics

Impedance (Ω)       75±3
Capacitance (pF/m)    52±2
Velocity of Propagation(﹪)   85.0
Sparker Test 4000

Return Loss   5-1000MHz(dB) 

≥22

Return Loss  1000-3000MHz(dB)   

≥20

 

Attenuation(@20℃)

Frequency (MHZ)   Min Attenuation (dB/100ft)   Max Attenuation (dB/100m) 
 5 0.9 2.8
55 2.1 6.7
187 3.6 11.8
211 3.8 12.5
400 5.1 16.7
500 5.7 18.7
750 7.0 22.8
860 7.5 24.6
1000 8.0 26.3
1500 9.9 32.5
1800 10.9 35.6
2200 12.6 41.2

 

TYPE Conductor Insulation Braid Shield Jacket

Nom.

Imped

Ohm

Nom.

Capa.

pF/m

Attenuation

100MHz

db/Km

  No./mm MTRL mm MTRL No./mm No./mm MTRL

O.D

mm

MTRL      
RG-6/U 1/1.02 BC 4.57 FPE AF 95% TC 6.9 PVC 75 55 94
RG-8/U 7/0.9 BC 7.24 FPE 95% - BC 10.3 PVC 52 85 64
RG-8/U 7/0.724 BC 7.24 PE 95% - BC 10.3 PVC 52 97 70
RG-8/X 19/0.287 BC 3.94 FPE 95% - BC 6.15 PVC 52 85 121
RG-11/U 1/1.63 BC 7.24 FPE DF 75% TC 10.3 PVC 75 57 49
RG-14/U 1/2.591 BC 9.4 PE 97% 97% BCBC 13.8 PVC 52 97 50
RG-58/U 1/0.8 BC 2.9 PE 95% - TC 5.0 PVC 50 94 140
RG-58A /U 19/0.203 TC 2.9 FPE AF 97% TC 5.03 PVC 50 86 131
RG-58A /U 19/0.18 TC 2.95 PE 95% - TC 4.95 PVC 50 102 160
RG-58C /U 19/0.18 TC 2.95 PE 95% - TC 4.95 NC-PVC 50 102 160
RG-59/U 7/0.254 BC 3.71 FPE 95% - BC 6.15 PVC 75 57 98
RG-59/U 1/0.81 BC 3.71 FPE AF 85% BC 6.15 PVC 75 57 98
RG-59/U 1/0.643 CCS 3.71 PE 95% - BC 6.15 PVC 73 69 120
RG-59A /U 17/0.16 BC 3.71 PE 95% - BC 6.15 NC-PVC 73 69 120
RG-59B/U 1/0.584 CCS 3.71 PE 95% - BC 6.15 NC-PVC 75 67 120
RG-62/U 1/0.643 CCS 3.71 SSPE 95% - BC 6.15 PVC 93 44 83
RG-62A /U 1/0.643 CCS 3.71 SSPE 95% - BC 6.15 NC-PVC 93 44 83
RG-62B/U 7/0.203 CCS 3.71 SSPE 95% - BC 6.15 NC-PVC 93 44 100
RG-71B/U 1/0.643 CCS 3.71 SSPE 95% 95% TCTC 6.22 PE 93 44 84
RG-174/U 7/0.16 CCS 1.52 PE 95% - TC 2.8 PVC 50 100 260
RG-174A /U 7/0.16 CCS 1.52 PE 95% - TC 2.8 NC-PVC 50 100 260
RG-212/U 1/1.412 SC 4.7 PE 97% 97% SCSC 8.4 NC-PVC 50 98 87
RG-213/U 7/0.752 BC 7.24 PE 95% - BC 10.3 NC-PVC 50 98 70
RG-214/U 7/0.752 SC 7.24 PE 97% 97% SCSC 10.8 NC-PVC 50 98 67
RG-216/U 7/0.404 TC 7.24 PE 97% 97% BCBC 10.8 PVC 75 67 72
RG-223/U 1/0.90 SC 2.9 PE 97% 97% SCSC 5.3 NC-PVC 50 98 120

144*0.12AL Braiding USA Standard Rg6 Siamese Cable , Coaxial Cable For CCTV 0144*0.12AL Braiding USA Standard Rg6 Siamese Cable , Coaxial Cable For CCTV 1

144*0.12AL Braiding USA Standard Rg6 Siamese Cable , Coaxial Cable For CCTV 2

 

How to choose the right coaxial Cable-Material

 

1 Inner Conductor

SC(Silver Copper)

TC(Tined Copper)

BC(Bare Copper) or called CU have a good electrical performance and flexibility

CCA(Copper clad Aluminum) very Light but could be easier oxidized(rusted)

CCS(Copper clad steel) Cheap(price only 1/5 of BC) and not bad electrical performance

 

the cost is Silver copper>tinned copper>bare copper>Copper clad aluminum>Copper clad steel

 

2 Insulation

Solid PE/Foam PE/ Gas Injection PE

Currently there is two type of PE in the market for the Drop Cables,

Local PE(Chinese Manufacture)

Imported PE( DOW chemical..)

 

The main difference of the two type, is that Local PE is not pass the Oxidative induction time(OIT) Test, and the Crush resistant Test, which may required by the CATV company, but general the electrical performance is the same.

 

The price difference of the material is about 23%...

 

3 Foil Screen

Normally it is in three type

AL or copper foil not bonded to the insulation ---AP

AL or copper foil bonded to the insulation- Bonded Al/Pet(blue)- BAP(the most widely used)

AL/PET/AL foil bonded to the insulation- Bonded Al/Pet/AL- BAPA

I have meet some customer that want a copper color Al foil(some clients called golden foil), which is the same color of the copper foil, but it is Al foil. WOW--a lot lot cheaper,, scratch on the foil, you will see or burn it.

One more thing is the overlap of the foil, >2mm or >20%, you need to know from your supplier

 

4 Braiding

For the braiding wire, there is:

BC Copper wire,

TC Tinned copper wire,

SC Silvered copper wire,

CCA Copper clad Aluminum wire, looks like BC but could be easier oxidized(rusted)

AL Magnesium Aluminum Wire, (the most widely used)

the cost is Silver copper wire>tinned copper wire>copper wire>Copper clad aluminum wire> Aluminum wire

 

With a knife or lighter you can tell the difference

Another difference of the cost, is the braiding coverage, form 30%-95%, normally in the market is 48%, 60%, 77%, for the digital cable, is over 90%.

 

5 Jacket

The requirement for PVC included

1 Tensile strength before aging

2 Elongation before aging

3 Tensile strength after aging

4 Elongation after aging

5 Shrinkage

6 Heat shock

7 Cold bend

8 Cold Impact

9 UV Resistant

10 Fire resistant( include different grade, for north american market, there is CMX,CM,CMR/Riser,CMP/ Plenum, for European, it is IEC60332-1, IEC 60332-3, IEC60332-3C)

 

The more requirement you need, the more expensive the material.

For the Tropical area, you might just need the 1,2,9, and that would be enough,

For the cold area, you might need the 7, 8, but still you need to know your lowest temperature, other wire, the jacket will be break, and you have to reinstall, or get the customer complaint.

For commercial building , first resistant CMR, CMP is recommend.

 

Once more, for the fire resistant PVC , it is better to get the certification online check like UL/ETL, if they pass, you can find the relevant information of the company. and you might need to send it to test like half a year or once year from the mass production to be more sure

144*0.12AL Braiding USA Standard Rg6 Siamese Cable , Coaxial Cable For CCTV 3

 

If you have technical support from an engineer, please let us know the type of cables you need, the inner conductor, the braiding coverage, the jakcet material and color, the packing length and design, and the application. We will help you choose the most suitable cable.

 

If you are not sure about certain specifications of the electric cables, please let us know your inquiry and we are very happy to give you professional technical advice and support services. Our company offer specific cables and wires consulting, design, OEM and manufacturing based on the customer's requirements and application scenarios to help customers create more business opportunities.

 

Mobile/ Whatsapp: +86 13616872763 | QQ/ Wechat: 398023701 | Skype: thomas-aite | Email: thomas@at-cable.com